ASoC: wcd-mbhc: Disable moisture_en when duty cycle is enabled
Moisture Detection should be disabled at init if duty cycle is enabled. Change-Id: If398928a680174d981b9baefe02d9efd4e21766e Signed-off-by: Vatsal Bucha <vbucha@codeaurora.org>
This commit is contained in:
@@ -1,5 +1,5 @@
|
||||
// SPDX-License-Identifier: GPL-2.0-only
|
||||
/* Copyright (c) 2015-2018, The Linux Foundation. All rights reserved.
|
||||
/* Copyright (c) 2015-2019, The Linux Foundation. All rights reserved.
|
||||
*/
|
||||
#include <linux/module.h>
|
||||
#include <linux/init.h>
|
||||
@@ -850,7 +850,7 @@ static bool wcd_mbhc_moisture_detect(struct wcd_mbhc *mbhc, bool detection_type)
|
||||
{
|
||||
bool ret = false;
|
||||
|
||||
if (!mbhc->mbhc_cfg->moisture_en ||
|
||||
if (!mbhc->mbhc_cfg->moisture_en &&
|
||||
!mbhc->mbhc_cfg->moisture_duty_cycle_en)
|
||||
return ret;
|
||||
|
||||
@@ -1342,9 +1342,15 @@ static int wcd_mbhc_initialise(struct wcd_mbhc *mbhc)
|
||||
else
|
||||
WCD_MBHC_REG_UPDATE_BITS(WCD_MBHC_HS_L_DET_PULL_UP_CTRL, 3);
|
||||
|
||||
/* Configure for moisture detection when duty cycle is not enabled.
|
||||
* Otherwise disable moisture detection.
|
||||
*/
|
||||
if (mbhc->mbhc_cfg->moisture_en && mbhc->mbhc_cb->mbhc_moisture_config
|
||||
&& !mbhc->mbhc_cfg->moisture_duty_cycle_en)
|
||||
mbhc->mbhc_cb->mbhc_moisture_config(mbhc);
|
||||
else if (mbhc->mbhc_cfg->moisture_duty_cycle_en &&
|
||||
mbhc->mbhc_cb->mbhc_moisture_detect_en)
|
||||
mbhc->mbhc_cb->mbhc_moisture_detect_en(mbhc, false);
|
||||
|
||||
/*
|
||||
* For USB analog we need to override the switch configuration.
|
||||
|
Reference in New Issue