msm: camera: csid: Fix the EOT IRQ Reception for Sensors with EPD
Sensors with EPD feature do not subscribe to the ERROR_EOT IRQ. However, the CSID IRQ mask do not prevent from setting the IRQ status, it only prevents the IRQ from getting fired. Add check in csid irq to prevent detecting the EOT for Sensors with EPD. CRs-Fixed: 2798458 Change-Id: I8e029834918326b70154a989fbdff747de7851ed Signed-off-by: Jigar Agrawal <jigar@codeaurora.org>
Bu işleme şunda yer alıyor:
@@ -4927,8 +4927,9 @@ irqreturn_t cam_ife_csid_irq(int irq_num, void *data)
|
||||
fatal_err_detected = true;
|
||||
goto handle_fatal_error;
|
||||
}
|
||||
if (irq_status[CAM_IFE_CSID_IRQ_REG_RX] &
|
||||
CSID_CSI2_RX_ERROR_CPHY_EOT_RECEPTION) {
|
||||
if ((irq_status[CAM_IFE_CSID_IRQ_REG_RX] &
|
||||
CSID_CSI2_RX_ERROR_CPHY_EOT_RECEPTION) &&
|
||||
(!csid_hw->epd_supported)) {
|
||||
CAM_ERR_RATE_LIMIT(CAM_ISP,
|
||||
"CSID:%d CPHY_EOT_RECEPTION",
|
||||
csid_hw->hw_intf->hw_idx);
|
||||
|