Преглед на файлове

qcacld-3.0: Reduce hif usb remove time when card surprise-removed

qcacld-2.0 to qcacld-3.0 propagation

In USB solution, hif_usb_remove costs ~25s after card unplugged.
Test step is simple, do p2p listen, then unplug card. Sme session
close costs 15s. When do p2p listen, scan will be issued to fw, but this
cmd is stuck in smeScanCmdActiveList which cause session close cmd
eSmeCommandDelStaSession blocked and the timeout is 15s.

This solution is that remove scan from smeScanCmdActiveList
if scan cmd pending in active list when close session.

Change-Id: I9f1af72cefe80dca056d7a23e015caa746952330
CRs-Fixed: 1068739
(cherry picked from commit b3460026a8ae119ac660b3970c9e3cc8b999656d)
Kai Liu преди 8 години
родител
ревизия
7f07073647
променени са 1 файла, в които са добавени 3 реда и са изтрити 0 реда
  1. 3 0
      core/sme/src/csr/csr_api_roam.c

+ 3 - 0
core/sme/src/csr/csr_api_roam.c

@@ -15708,6 +15708,9 @@ QDF_STATUS csr_roam_close_session(tpAniSirGlobal pMac, uint32_t sessionId,
 			purge_sme_session_cmd_list(pMac, sessionId,
 					   &pMac->sme.smeScanCmdPendingList);
 
+			purge_sme_session_cmd_list(pMac, sessionId,
+					   &pMac->sme.smeScanCmdActiveList);
+
 			purge_csr_session_cmd_list(pMac, sessionId);
 			status = csr_issue_del_sta_for_session_req(pMac,
 						 sessionId,