qcacmn: Enable 160 MHz Spectral scan in QCN9000

Till IPQ8074/IPQ8074_V2 each Spectral detector was capable of
doing scan up to 80 MHz. But in QCN9000 each Spectral detector
is capable of doing scan up to 160 MHz. As a result there will
be only one Spectral report in 160/80p80 MHz. Modify Spectral
Rx path to support single Spectral report in 160 MHz.

Change-Id: I9639cdc6adc6ad80e2769571b06d2a2021d699bc
CRs-Fixed: 2619544
Tento commit je obsažen v:
Edayilliam Jayadev
2020-03-13 09:14:22 +05:30
odevzdal nshrivas
rodič 171ac51c1a
revize 4e5b760643
5 změnil soubory, kde provedl 224 přidání a 130 odebrání

Zobrazit soubor

@@ -90,11 +90,14 @@ enum spectral_params {
* enum spectral_scan_mode - Spectral scan mode
* @SPECTRAL_SCAN_MODE_NORMAL: Normal mode
* @SPECTRAL_SCAN_MODE_AGILE: Agile mode
* @SPECTRAL_SCAN_MODE_MAX: Max number of Spectral modes
* @SPECTRAL_SCAN_MODE_INVALID: Invalid Spectral mode
*/
enum spectral_scan_mode {
SPECTRAL_SCAN_MODE_NORMAL,
SPECTRAL_SCAN_MODE_AGILE,
SPECTRAL_SCAN_MODE_MAX,
SPECTRAL_SCAN_MODE_INVALID = 0xff,
};
struct spectral_ioctl_params {