Add Rate Code Index macro for Smart Antenna 320 MHz BW in per PPDU stats processing path. Change-Id: I880cbc5d54f333dc2f8938c1a4d3bd56b96b7a6e CRs-Fixed: 3429317
@@ -116,6 +116,8 @@
#define CDP_DATA_NON_QOS_TID 16
#define CDP_NUM_SA_BW 4
+/* Smart Antenna 320MHz BW Phy MAX Rate Code Index */
+#define CDP_SA_BW320_INX 4
#define CDP_PERCENT_MACRO 100
#define CDP_NUM_KB_IN_MB 1000
/*
@@ -4168,7 +4168,7 @@ static void dp_process_ppdu_stats_user_cmpltn_common_tlv(
tag_buf++;
/* Extract 320MHz MAX PHY ratecode */
- ppdu_user_desc->sa_max_rates[bw_iter] =
+ ppdu_user_desc->sa_max_rates[CDP_SA_BW320_INX] =
HTT_PPDU_STATS_USER_CMPLTN_COMMON_TLV_MAX_RATES_GET(*tag_buf);
}