@@ -967,6 +967,9 @@ typedef enum {
|
|
|
/** unified request for LL stats and get station cmds */
|
|
|
WMI_REQUEST_UNIFIED_LL_GET_STA_CMDID,
|
|
|
|
|
|
+ /** request for thermal stats */
|
|
|
+ WMI_REQUEST_THERMAL_STATS_CMDID,
|
|
|
+
|
|
|
|
|
|
/** ARP OFFLOAD REQUEST*/
|
|
|
WMI_SET_ARP_NS_OFFLOAD_CMDID = WMI_CMD_GRP_START_ID(WMI_GRP_ARP_NS_OFL),
|
|
@@ -28369,6 +28372,33 @@ typedef struct {
|
|
|
A_UINT32 prio;
|
|
|
} wmi_therm_throt_level_config_info;
|
|
|
|
|
|
+typedef enum {
|
|
|
+ WMI_THERMAL_TEMP_RANGE_STATS_NONE = 0,
|
|
|
+ WMI_THERMAL_TEMP_RANGE_STATS_INIT,
|
|
|
+ WMI_THERMAL_TEMP_RANGE_STATS_REQUEST,
|
|
|
+ WMI_THERMAL_TEMP_RANGE_STATS_CLEAR,
|
|
|
+ WMI_THERMAL_STATS_CURRENT_ALL_SENSORS_TEMP,
|
|
|
+} wmi_thermal_stats_action;
|
|
|
+
|
|
|
+typedef struct {
|
|
|
+ /** TLV tag and len; tag equals
|
|
|
+ * WMITLV_TAG_STRUC_wmi_thermal_stats_cmd_fixed_param
|
|
|
+ */
|
|
|
+ A_UINT32 tlv_header;
|
|
|
+ /*
|
|
|
+ * Configure thermal temperature offset value for capturing
|
|
|
+ * thermal stats in thermal range.
|
|
|
+ * FW already has thermal throttling threshold temperature in BDF.
|
|
|
+ * Thermal STATS start capturing from temperature threshold to
|
|
|
+ * temperature threshold + offset.
|
|
|
+ * If thermal offset is 0 then thermal STATS capture is disabled.
|
|
|
+ *
|
|
|
+ * Units of thermal_offset are degrees Celsius.
|
|
|
+ */
|
|
|
+ A_UINT32 thermal_offset;
|
|
|
+ A_UINT32 thermal_action; /* refer to enum wmi_thermal_stats_action */
|
|
|
+} wmi_thermal_stats_cmd_fixed_param;
|
|
|
+
|
|
|
typedef enum {
|
|
|
WMI_THERMAL_CLIENT_UNSPECIFIED = 0,
|
|
|
WMI_THERMAL_CLIENT_APPS = 1,
|
|
@@ -28408,6 +28438,8 @@ typedef enum {
|
|
|
WMI_THERMAL_SHUTDOWN_TGT = 3,
|
|
|
} WMI_THERMAL_THROT_LEVEL;
|
|
|
|
|
|
+#define WMI_THERMAL_STATS_TEMP_THRESH_LEVEL_MAX 5
|
|
|
+
|
|
|
/** FW response with the stats event id for every pdev and zones */
|
|
|
typedef struct {
|
|
|
/* TLV tag and len; tag equals WMITLV_TAG_STRUC_wmi_therm_throt_stats_event_fixed_param */
|
|
@@ -28419,10 +28451,10 @@ typedef struct {
|
|
|
A_UINT32 therm_throt_levels; /* number of levels in therm_throt_level_stats_info */
|
|
|
/* This TLV is followed by another TLV of array of structs
|
|
|
* wmi_therm_throt_level_stats_info therm_throt_level_stats_info[therm_throt_levels];
|
|
|
+ * wmi_thermal_throt_temp_range_stats temp_range_stats[therm_throt_levels];
|
|
|
*/
|
|
|
} wmi_therm_throt_stats_event_fixed_param;
|
|
|
|
|
|
-
|
|
|
typedef struct {
|
|
|
/** TLV tag and len; tag equals
|
|
|
* WMITLV_TAG_STRUC_wmi_therm_throt_level_stats_info */
|
|
@@ -28432,7 +28464,27 @@ typedef struct {
|
|
|
/* this number increments by one each time we are in this state and we finish one full duty cycle. */
|
|
|
} wmi_therm_throt_level_stats_info;
|
|
|
|
|
|
+typedef struct {
|
|
|
+ /** TLV tag and len; tag equals
|
|
|
+ * WMITLV_TAG_STRUC_wmi_thermal_throt_temp_range_stats
|
|
|
+ */
|
|
|
+ A_UINT32 tlv_header;
|
|
|
+ /**
|
|
|
+ * Temperature range to capture thermal stats between start to end
|
|
|
+ * temperature level.
|
|
|
+ */
|
|
|
+ A_UINT32 start_temp_level; /* unit in degC */
|
|
|
+ A_UINT32 end_temp_level; /* unit in degC */
|
|
|
|
|
|
+ /** Total time spent on each thermal stats level, units are milliseconds. */
|
|
|
+ A_UINT32 total_time_ms_lo;
|
|
|
+ A_UINT32 total_time_ms_hi;
|
|
|
+ /**
|
|
|
+ * Thermal stats counter for every time thermal stats level enters
|
|
|
+ * this temperature range.
|
|
|
+ */
|
|
|
+ A_UINT32 num_entry;
|
|
|
+} wmi_thermal_throt_temp_range_stats;
|
|
|
|
|
|
|
|
|
typedef enum {
|
|
@@ -29174,6 +29226,7 @@ static INLINE A_UINT8 *wmi_id_to_name(A_UINT32 wmi_command)
|
|
|
WMI_RETURN_STRING(WMI_VDEV_ENABLE_DISABLE_INTRA_BSS_CMDID);
|
|
|
WMI_RETURN_STRING(WMI_PEER_ENABLE_DISABLE_INTRA_BSS_CMDID);
|
|
|
WMI_RETURN_STRING(WMI_ROAM_MLO_CONFIG_CMDID);
|
|
|
+ WMI_RETURN_STRING(WMI_REQUEST_THERMAL_STATS_CMDID);
|
|
|
}
|
|
|
|
|
|
return "Invalid WMI cmd";
|